<ErrorNumber>22267</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Picker System pressure sensor is not calibrated. Run cal pressure
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Cal pressure requires the servce engineer to turn off the supply
air pressure and then the firmware takes a reading of the sensor
offset and saves this.  If this offset is zero, then the
cal pressure has probably never been set and all the thresholds
will be in error.  Similar error for main system pressure sensor.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Call Creo Service.
</text></DescriptionText>
</OperatorAction>
<Cause>
al aoff[5] is zero.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cfg_aoff.xml</LinkAddress><LinkTitle>NVS: al aoff</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>